Aluminum Cooling Blocks

Kelabscience aluminum cooling blocks for tubes and PCR plates are reusable benchtop holders with silicone support bases. After pre-chilling, they provide passive cooling during sample preparation. The 13 configurations range from 4 to 384 positions, with models for PCR tubes, microcentrifuge tubes and larger centrifuge tubes, plus a dedicated block for compatible 384-well PCR plates.

Product Info

Choosing a 96-Well Tube Cooling Block

The blue module pictured has eight rows marked A–H and twelve columns numbered 1–12, so each tube position can be matched to a sample list. Kelabscience offers two 96-position models with different hole sizes and footprints.

  • KL-ATB-096A is designed for selected 0.2 and 0.5 mL tubes. For 0.2 mL PCR tubes, compare the tube profile with the block’s 6 mm openings and 13 mm hole depth. The block occupies 119 × 87 mm of bench space.
  • KL-ATB-096B has 11 mm openings, 26 mm deep, for 1.5 and 2 mL microcentrifuge tubes. Its footprint is 224 × 152 mm.

Single-Size and Mixed-Tube Configurations

For a smaller microcentrifuge tube cooling block, KL-ATB-024 and KL-ATB-040 offer 24 and 40 positions for 1.5 or 2 mL tubes. If you handle 0.2 mL tubes alongside 1.5 or 2 mL tubes, the 48-, 60-, 103- and 106-position models combine 6 mm and 11 mm openings in one module.

For centrifuge tubes, KL-ATB-008 has eight positions for 5 mL tubes, KL-ATB-006 has six for 10 or 15 mL tubes, and KL-ATB-004 has four for 50 mL tubes. For mixed tube sizes, KL-ATB-007 has seven positions with 16 mm and 29 mm openings for selected 10, 15 and 50 mL tubes.

For plate-based preparation, KL-ATB-384 supports compatible 384-well PCR plates on the bench.

Passive Cooling During Sample Preparation

The silicone base supports the aluminum module while tubes are loaded, opened and removed. When samples require chilled handling, pre-cool the empty assembly before use. The aluminum absorbs heat from the warmer tubes and the surrounding air, so the block gradually warms on the bench. Tube taper and seating depth affect contact with the well wall.

Bulk Supply and Ordering

For a quotation, send the block SKU and quantity required. If you are still choosing a model, share the part number or dimensional drawing of your tube or plate. For a mixed-tube layout, tell us how many tubes of each size you need to hold at the same time. We can review the layout and confirm pack quantities with your quotation.

Specification

Model Specifications

Kelabscience SKU Positions Nominal tube size or plate format Hole diameter (mm) Hole depth (mm) L × W × H (mm)
KL-ATB-004 4 50 mL 28 50 70 × 70 × 55
KL-ATB-006 6 10 or 15 mL 16 50 109 × 39 × 54
KL-ATB-007 7 10, 15 or 50 mL 16 / 29 50 106 × 70 × 54
KL-ATB-008 8 5 mL 17 40 89 × 49 × 48
KL-ATB-024 24 1.5 or 2 mL 11 24 118 × 77 × 30
KL-ATB-040 40 1.5 or 2 mL 11 23 143 × 95 × 25
KL-ATB-048 48 0.2, 1.5 or 2 mL 6 / 11 13 / 27 118 × 77 × 30
KL-ATB-060 60 0.2, 1.5 or 2 mL 6 / 11 13 / 27 118 × 77 × 30
KL-ATB-096A 96 0.2 or 0.5 mL 6 13 119 × 87 × 20
KL-ATB-096B 96 1.5 or 2 mL 11 26 224 × 152 × 30
KL-ATB-103 103 0.2, 1.5 or 2 mL 6 / 11 13 / 27 109 × 101 × 33
KL-ATB-106 106 0.2, 1.5 or 2 mL 6 / 11 14 / 26 160 × 86 × 29
KL-ATB-384 384 Compatible 384-well PCR plate 4 7 129 × 88 × 23

For mixed-hole models, the position count is the total across all hole sizes. Confirm the number of positions available for each tube size when selecting a layout.

Materials and Handling

Parameter Specification
Construction Reusable aluminum module with silicone support base
Cooling method Passive cooling after pre-chilling
Suggested initial pre-chilling Approximately 12–24 hours at −20 °C for the empty, assembled block. Verify the starting temperature for the intended application.
Benchtop working time Depends on block temperature, room conditions, sample volume and tube fit
Packaging Pack quantity confirmed at quotation

FAQ

Q1. What should I check when choosing a PCR tube cooling block for strip tubes?

Compare the outside diameter and taper of each tube with the hole diameter and depth. For strips, also check the center-to-center spacing between adjacent tubes. The full strip should seat evenly, with enough clearance to open and close the caps.

Q2. Which centrifuge tube cooling block can hold both 15 mL and 50 mL tubes?

KL-ATB-007 combines 16 mm and 29 mm openings across seven positions and is specified for selected 10, 15 and 50 mL tubes. If your batch needs a particular mix of 15 mL and 50 mL tubes, request the position count for each diameter before ordering.

Q3. How long will a pre-chilled block keep my samples cold on the bench?

The working interval depends on the block’s starting temperature, room conditions, sample volume and contact between the tube and the well. To establish an interval for your setup, monitor a representative filled tube during normal handling and record how long the sample stays within its required temperature range.

Q4. How can I check whether my 384-well PCR plate fits KL-ATB-384?

KL-ATB-384 has 4 mm openings with a hole depth of 7 mm. Compare the plate’s well spacing and underside profile with the block layout. If the plate has a skirt, check the clearance around its lower edge so the wells can seat correctly during benchtop preparation.

Q5. How should I clean the aluminum module and silicone base between uses?

Use a non-abrasive cleaning method suitable for both aluminum and silicone. For disinfection, confirm that the agent and contact time are compatible with both materials. Dry the components before pre-chilling or storage. If your procedure calls for steam sterilization, check suitability for the specific model and cycle first.